PROJECT <<243 SE 1322 DISTRIBUCION CENTRO (5TA. FASE)>> CONTRACT PIF-010/2014

  • SE Estancita Bco. 1 (1t-3f-20 MVA-115/23 kV 2/5 A+ 1.2 MVAr-23 kV). Includes: 5.77 km of circuit of 23 kV.
  • SE Ameca Bco. 1 (1t-3f-20 MVA-115/23 kV 2/5 A+ 1.2 MVAr-23 kV). Includes: 1.5 km of circuit of 23 kV.
  • SE Guevara Ampl. (1 feeder-115 kV).
  • SE Tecolotlan Bco. 1. 1t-3f-20 MVA-115/23 kV 2/4 A+ 1.2 MVAr-23kV. Includes 0.72 km of circuit of 23 kV.
  • SE San Clemente Bco. 1. 1t-3f-20 MVA-115/23 kV 2/6 A+ 1.2 MVAr-23 kV. Includes 1.47 km of circuit of 23 kV.
  • LT Cocula-Ameca (115 kV-1c-32.3 km-795 ACSR-TA/PT/800 mm2-Al-XLP).
  • LT Ameca-Guevara (115 kV-1c-42.1 km-795 ACSR-TA/PT/800 mm2-Al-XLP).
  • LT Cocula Entq. Acatlan-Tecolotaln (115 kV-2c-4.1 km-795 ACSR-TA/PT/800 mm –AL-XLP).
  • LT San Clemente-Acatlan (115 kV-1c-59.58 km-477 ACSR- TA/PT/800 mm2-AL-XLP).
  • LT San Clemente-Mezquitan (115 kV-1c-32.82 km-477 ACSR-TA/PT).